Model
|
Installation Size
|
Outline Size
|
Installation Hole |
Weight (KG ≈ )
|
|||
A(mm)
|
B(mm)
|
W(mm)
|
H(mm)
|
D(mm)
|
|||
MZ590-0075G-T4
|
186
|
306
|
210
|
330.5
|
188
|
Ø9.5
|
7.5
|
MZ590-0110G-T4
|
|||||||
MZ590-0150G-T4
|
|||||||
MZ590-0185G-T4
|
|||||||
MZ590-0220G-T4
|
|||||||
MZ590-0300G-T4
|
|||||||
MZ590-0370G-T4
|
238
|
396
|
260
|
420
|
196
|
Ø8.5
|
12.5
|
MZ590-0450G-T4
|
|||||||
MZ590-0550G-T4
|
272
|
455
|
304
|
470
|
240
|
Ø9
|
22.9
|
MZ590-0750G-T4
|
200
|
614
|
278
|
630
|
310
|
Ø9
|
37.7
|
Model MZ590-****G |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
****G | 0075G | 0110G | 0150G | 0185G | 0220G | 0300G | 0370G | 0450G | 0550G | 0750G | |||||
Rated power (kW) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |||||
Rated current (A) | 17 | 25 | 32 | 37 | 45 | 60 | 75 | 91 | 112 | 150 | |||||
Maximum Holding Current (A) Continuous 60s | 25.5 | 37.5 | 48 | 55.5 | 67.5 | 90 | 112.5 | 136.5 | 168 | 225 | |||||
Power Supply Input | Rated Voltage and Frequency | 3-phase 350, 380, 400, 420, 50/60Hz | |||||||||||||
Allowed Voltage Range | ±15% | ||||||||||||||
Allowed Frequency Range | ±5% | ||||||||||||||
Brake Resistance |
kW
|
1 | 1.5 | 1.5 | 2.5 | 2.5 |
3
|
4 | 5 | 6 | 8 | ||||
Ω |
≥ 65
|
≥ 43
|
≥ 32
|
≥ 22
|
≥ 22
|
≥ 16
|
≥ 16
|
≥ 16 | ≥ 16 | ≥ 12 | |||||
Resolver Signal Cable (according to model) | ZF80-**** stands for cable length, unit: cm. For example, ZF80-400 means that the cable length is 4 meters. | ||||||||||||||
Pressure Sensor (necessary) | Could choose a variety of pressure sensors, the measuring range selection corresponding to parameters A-03 (the measuring range of pressure sensor), recommended Danfoss 060G3557. | ||||||||||||||
Breaker | 50 | 50 | 75 |
60
|
75
|
100
|
100
|
150
|
150
|
200
|
300
|
||||
Contactor | 30 | 30 | 50 | 50 | 50 | 50 | 80 |
100
|
100
|
160
|
250
|
||||
Basic Function |
Max frequency Maximum Frequency |
300Hz | |||||||||||||
Carrier Frequency |
1KHz~8KHz; the carrier frequency could automatically adjusted based on the load features.
|
||||||||||||||
Input Frequency Resolution |
Digital setting: 0.01Hz; Analog setting: maximum frequency × 0.1% |
||||||||||||||
Control Mode | Closed-loop vector control (VC); V/F control | ||||||||||||||
Starting Torque | 0Hz/180% (VC) | ||||||||||||||
Speed Range | 1:1000 (VC) | ||||||||||||||
Steady Speed Precision | ±0.02% (VC) | ||||||||||||||
Torque Control Precision | ±5% (VC) | ||||||||||||||
Overload Capacity |
150% rated output current: 60s 180% rated output current: 3s |
||||||||||||||
Auto Voltage Regulation (AVR) | It can keep constant output voltage automatically when the network voltage changes. | ||||||||||||||
Protection Function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection and overload protection | ||||||||||||||
Environment
|
Installation Location |
Indoor, free from direct sunlight, dust, corrosive gas, combustible gas,oil smoke, vapour, drip or salt.
|
|||||||||||||
Altitude | Lower than 1000m (decrease if higher than 1000m) | ||||||||||||||
Ambient Temperature | -10°C ~ +40°C (decrease if the ambient temperature is between 40°C and 50°C) | ||||||||||||||
Humidity | Less than 95%RH, without condensing | ||||||||||||||
Vibration | Less than 5.9 m/s² (0.6g) | ||||||||||||||
Storage Temperature | -20°C ~ +60°C | ||||||||||||||
IP Level | IP20 |