220V/380V 50/60Hz Single/Three Phase Variable Frequency Drive

220v 380v 50 60hz single phase three phase variable frequency drive
220v 380v 50 60hz single phase three phase variable frequency drive

EV510H series high performance VFD

EV510H series high-performance VFD, with small size, light weight, easy to carry and other characteristics, is a functional enhanced product.
The variable frequency drive can be used for driving textile, paper making,silk weaving, machine tool packaging, food, fan,water pump and various kinds of automatic production equipments.
Variable Frequency Drive Naming rules

Rated specification
Model Power capacity (kVA) Input current (A) Output current (A) Match motor (kW)
Single phase: 220V, 50/60Hz
EV510H-0004G-S2 1.0 5.4 2.3 0.4
EV510H-0007G-S2 1.5 8.2 4.0 0.75
EV510H-0015G-S2 3.0 14.0 7.0 1.5
EV510H-0022G-S2 4.0 23.0 9.6 2.2
Three phase: 380V, 50/60Hz
EV510H-0007G-T4 1.5 3.4 2.1 0.75
EV510H-0015G-T4 3.0 5.0 3.8 1.5
EV510H-0022G-T4 4.0 5.8 5.1 2.2
EV510H-0037G/0055P-T4 5.9 10.5 9.0 3.7
EV510H-0055G/0075P-T4 8.9 14.6 13.0 5.5

Technique Feature
Item Specification
Highest frequency Vector control: 0~500Hz; V/F control: 0~500Hz
Carrier frequency 0.8kHz~12kHz The carrier frequency can be automatically adjusted according to the temperature characteristics.
Input frequency resolution Digital setting: 0.01Hz; Analog setting: maximum frequency × 0.025%
Control mode Open-loop vector (SVC); V/F control
Start torque G Type: 0.5Hz/150% (SVC); P Type: 0.5Hz/100%
Speed range 1:100 (SVC)
Speed control accuracy ±0.5% (SVC)
Overload capacity G Type: 150% Rated current 60sec; 180% Rated current 3sec
P Type: 120% Rated current 60sec; 150% Rated current 3sec
Torque boost Automatic torque increase; Manual torque increase 0.1%~30.0%
V/F curve Three types: linear type; multi-point type; the nth power of V/F curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)
ACC/DEC curve Two types: full separation, half of separation
DC brake DC brake frequency: 0.00Hz~max frequency
Brake time: 0.0s~36.0s
Brake action current: 0.0%~100.0%
JOG control JOG frequency range: 0.00Hz~50.00Hz. JOG speed-up/down time: 0.0s~6500.0s
Simple PLC multi-stage speed running
Via bul-in PLC or control terminal can realze max 16 stage speed running
Built-in PID Can realize process control closed-loop system conveniently
Auto adjust voltage (AVR) When grid voltage changes, can keep output voltage steadily automatically
Overcurrent and overvoltage speed control During limit current and voltage automatically, protect from tripping off frequently for overvoltage and overcurrent
Quick current-limit function Reduce overcurrent error on max extent, protect inverter normal running
Torque limitation and control "Digger" feature, inverter could limit torque automatically, prevent overcurrent tripping off; close-loop vector can realize torque control
Outstanding performance Using high-performance vector control
Instantaneous stop not stop During instant power-off, by motor feedback energy, inverter compensates voltage-drop to keep running for a short time
Timing control Timing control function: setting time range: 0.0min~6500.0min
Command source Control panel, control terminal, communication; can be switched by several modes
Frequency source / Auxiliary frequency sources Digital setting, analog voltage setting, analog current setting, pulse setting, communication setting, can be switched by several methods
Input terminal 5 digital input terminals, one of them supports max 100KHz HS pulse input (apolegamy).
2 analog input terminals; AI2 supports 0~10V voltage input; AI1 supports 0~10V voltage input or 0~20mA current input
Output terminal 1 high-speed pulse output terminal (optional open collector), supports 0~100KHz pulse (apolegamy).
1 relay output terminal.
1 analog output terminal, supports 0~20mA current output
LED display Can display parameters
Press-key locking and function selection Realize press-key partial or full locking, define part press-key function range, to avoid wrong operation
Protection function Power-on motor short circuit test, output phase-loss protection, over-current protection, over-voltage protection, under-voltage protection, overheating protection, overload protection, overload protection etc
Application site Indoor, without direct sunlight, no powder, corrosive gas, combustion air, oil dust, water steam, water drop or salt etc
Altitude level Less than 1000m, Derating above 1000m, Rated output current decreases by 1% every 100m
Environment temperature -10℃~+40℃ (During 40℃~50℃, please reduce capacity to use)
Humidity ≤95%RH, no water drop condensed

Keypad outline
Keypad outline


Panel tray size
Panel tray size


Outline size
Outline size

Model
Outlinesize (mm)
Installation hole
B
W
H
D
EV510H-0004G-S2
155
84
170
127
Ф5.7
EV510H-0007G-S2
EV510H-0015G-S2
EV510H-0022G-S2
EV510H-0007G-T4
EV510H-0015G-T4
EV510H-0022G-T4
EV510H-0037G/0055P-T4
183
91
193
142
Ф4.7